Automatic command

Are commands for general, security-related automatic systems in the control centre (Shadowing-, Temperature-, Heat-, or Input program). Automatic commands are not executed in the case of an active automatic lock.

Automatic lock

In case of active automatic lock of the motor control, no commands are executed by the control centre (except security commands). The automatic lock is reset by means of a time control. Automatic lock active = LED on the sensing device lights up No automatic lock = LED on the sensing device remainsdark

Channel

Connection of motor to the control device. A control device with e.g. 2 channels can activate two motors

Control

The following controls are possible:
– local control
– group control
– sector control
– central control

Detection of the end position

Automatic identification of the limit switch in the motor. The delay is calibrated by this and falls immediately after reaching the lower stop position or it will signal error detection. By the permanent calibration, Ächanges are identified and compensated for in the motor (e.g. changes in speed due to thermal differences, weathering etc.).

Drive command

Generic term for commands, which actuate a drive motion on the motor (Start, Shut, P1, P2, P3, P4, see-saw, Height, Angle).

Last position

Differentiated into the following “last positions” – Local command (from the electronic control) – central control (from the control centre, or in the System as “central” effective command is repeated) – Automatic command (the last command of an automatic system is from the control centre)

local command

Command to the electronic control from a local operation, central or other bus command, which performs the function of a local operation. (e.g. the command is not executed in the case of security system which activates an automatic lock etc.).

Local operation

Operation, which is connected directly to the electronic control unit. (physical sensing device)