PS24-1500 Power supply 24V DC / 1500mA

Power supply for all products which need a supply voltage of 24V DC.
The device is short-circuit-proof and suitable for an input voltage of 85-265V.

Technical data
– N-System DIN-rail mounted device 4,5 SU
– Input: 85V-265V / 50-60Hz
– Output: 24VDC / 1500mA

LSL – Limit switch for light

Universally applicable limit switch for the brightness-dependent control of electrically operated exterior blinds, awnings, etc. Incl. External sensor for brightness measurement in the range of 2 – 80 kLux. Setting of the switching threshold via “Lux”-control on the device. Adjustable on and off delay for a stable system with variable mesuring values.

Technical data
– N-System DIN-rail mounted device 1 SU
– Sensor approx. 53 x 63 mm
– Power supply 230V/ 50Hz
– potential free control contacts (max. 230V/ 50Hz, 10A)
– Measuring range 2 – 80 kLux

LSW – Limit Switch for Wind

Universally applicable limit switch for the wind monitoring to protect electrically operated exterior blinds, awnings, etc. Incl. outer sensor for the measuring range from wind force 2-8. The wind sensor is supplied with potential-free low voltage (PELV) through the limit switch.
LED display when the set limit value is exceeded. Adjustable on and off delay for a stable system with variable mesuring values. Setting whether the relay contact is limited in the event of an alarm (impulse) or permanently activated.

 

Technical data
– N-System DIN-rail mounted device 1 SU
– Sensor approx. 70 x 105 mm
– Power supply 230V/ 50Hz
– potential free control contacts (max. 230V/ 50Hz, 10A)
– Measuring range wind force 2 – 8

GC-02 Group Control for 2 motors

Control relay for controlling blinds and roller shutter motors with mechanical or electronic limit switches. For parallel operation of up to 2 blind or roller shutter motors without unallowed parallel switching of the drives. When more than 2 motors are controlled, it is possible to connect several group controllers in parallel.
Central control input for simultaneous driving of all connected motors. Blind switches or push buttons, timers, KNX blind actuators and various control devices with potential-free contacts can be used.

Technical data
N-System DIN-rail mounted device 4 SU
– Power supply 230V/ 50Hz
– Control voltage 230V/ 50Hz
– Switch contacts 2A (AC1/ cos phi 0.6)

GC-04 Group Control for 4 motors

Control relay for controlling blinds and roller shutter motors with mechanical or electronic limit switches. For parallel operation of up to 4 blind or roller shutter motors without unallowed parallel switching of the drives. When more than 4 motors are controlled, it is possible to connect several group controllers in parallel.
Central control input for simultaneous driving of all connected motors. Blind switches or push buttons, timers, KNX blind actuators and various control devices with potential-free contacts can be used.

Technical data
N-System DIN-rail mounted device 6,5 SU
– Power supply 230V/ 50Hz
– Control voltage 230V/ 50Hz
– Switch contacts 2A (AC1/ cos phi 0.6)

COR-02-4L Isolating relay for 2 motors

The isolating relay is designed for the connection of two 230 V motors with 2 end switches. It is controlled by a central 4-pole connection. The unit does not need a separate feeder. Combinations with automatik control units like clock timer, sun and wind automatic with 230 V output are possible.

Technical data
– AP-housing 75 x 75 x 37 mm
– Protection class IP44
– Grid 230V/50Hz
– Motor 2 x 230 V AC/ 4A 2

COR-02-5L Isolating relay for 2 motors

The isolating relay is designed for the connection of two 230 V motors with 2 end switches. It is controlled by a central 5-pole connection. The unit needs a separate feeder. Combinations with automatik control units like clock timer, sun and wind automatic with 230 V output are possible.

Technical data
– AP-housing 75 x 75 x 37 mm
– Protection class IP44
– Grid 230V/50Hz
– Motor 2 x 230V AC/ 4A